Nulyte Smart Electrolyte Analyzer
Download Brochure
Compact, Economical and Easy to use
Excellent precision and reliability
Long life, maintenance free electrodes
Automatic Calibration, Standby Mode (manual & Automatic)
Extremely low cost per test
Principle: Direct measurement with in selection electrode (ISE).
Parameter Conversion: This functionality allows quick change of analyze.
Sample: Whole blood, serum, plasma, CSF and diluted urine (dilution ratio 1:5).
Measuring time: 65 sec. Data Storage: 600 serum/plasma, 100 urine, 100 QC.
Ambient conditions: Temperature 5oC - 40oC, < 85% non – condensing humidity.
Output: 128x64 graphics display with Y/N numeric keypad.
Printer: 24 column thermal printer, USB port.
Input Voltage: 100/115 VAC, 50-60 HZ or 220-VAC, 50-60Hz, 0.75amp. Size & Weight: 30.1 cm W x, 35.cmH x 30.6cm D, 8.260kg.
Features
Compact, Economical and Easy to use
Excellent precision and reliability
Long life, maintenance free electrodes
Automatic Calibration
Extremely low cost per test
Standby Mode (manual & Automatic)
Product Details
Application | : Hospital , Clinical, Laboratory |
---|---|
Sample | : Whole Blood, Plasma, Serum, Urine |
Calibration | : Automatic |
Accepts Sample from | : Sample, Tube/Cup |
Measures | : Na+, K+, Cl-, Ca++, Li+ |
Automation | : Fully Automatic |
User Input | : Keypad |
Type | : Portable |
Specifications
Parameters available,
Na, K, Cl, iCa, Li, pH, Hco3, PCO2, TCO2, AG, BE
Reagent Pack : 700ml
1100ml
300 test with each pack*
Technical Specifications
Principle : Direct measurement with in selection electrode (ISE).
Parameter Conversion : This functionality allows quick change of analyze.
Sample : Whole blood, serum, plasma, CSF and diluted urine (dilution ratio 1:5).
Measuring time : 65 sec.
Data Storage : 600 serum/plasma, 100 urine, 100 QC.
Ambient conditions : Temperature 5oC - 40oC, < 85% non – condensing humidity.
Output : 128x64 graphics display with Y/N numeric keypad.
Printer : 24 column thermal printer, USB port.
Input Voltage : 100/115 VAC, 50-60 HZ or 220-VAC, 50-60Hz, 0.75amp.
Size & Weight : 30.1 cm W x, 35.cmH x 30.6cm D, 8.260kg.
Calculated Parameters TCO2, PCO2, BE, AG
Measuring Range | CV % | |
---|---|---|
8-12 YEARS | 12-16 YEARS | ABOVE 16 |
Na + | 50.0-250.0 mmol/L | <1.0% |
K+ | 0.50-20.00 mmol/L | <2.0% |
Cl- | 45.0-200.0 mmol/L | <2.0% |
iCa++ | 1.0-20.0 mmol/L | <2.0% |
Li+ | 0.2-5 mmol/L | <2.0% |
pH | 6.00-8.00 | <2.0% |
HCO3 | 22-28 mmol/L | <2.0% |
Inbuilt Parameter Selection
Mode A | Na/K/Cl |
Mode B | Na/K/iCa |
Mode C | Na/K/iCa/pH |
Mode D | Na/K/iCa/Cl |
Mode E | Na/K/iCa/Li |
Mode F | Na/K/iCa/pH/Cl |
Mode G | /K/iCa/pH/Cl/HCO3 |