Nulyte Smart Electrolyte Analyzer

Download Brochure

Compact, Economical and Easy to use
Excellent precision and reliability
Long life, maintenance free electrodes
Automatic Calibration, Standby Mode (manual & Automatic)
Extremely low cost per test

Principle: Direct measurement with in selection electrode (ISE). Parameter Conversion: This functionality allows quick change of analyze. Sample: Whole blood, serum, plasma, CSF and diluted urine (dilution ratio 1:5). Measuring time: 65 sec. Data Storage: 600 serum/plasma, 100 urine, 100 QC. Ambient conditions: Temperature 5oC - 40oC, < 85% non – condensing humidity. Output: 128x64 graphics display with Y/N numeric keypad. Printer: 24 column thermal printer, USB port. Input Voltage: 100/115 VAC, 50-60 HZ or 220-VAC, 50-60Hz, 0.75amp. Size & Weight: 30.1 cm W x, 35.cmH x 30.6cm D, 8.260kg.

Features

Compact, Economical and Easy to use
Excellent precision and reliability
Long life, maintenance free electrodes
Automatic Calibration
Extremely low cost per test
Standby Mode (manual & Automatic)

Product Details

Application : Hospital , Clinical, Laboratory
Sample : Whole Blood, Plasma, Serum, Urine
Calibration : Automatic
Accepts Sample from : Sample, Tube/Cup
Measures : Na+, K+, Cl-, Ca++, Li+
Automation : Fully Automatic
User Input : Keypad
Type : Portable

Specifications

Parameters available,
Na, K, Cl, iCa, Li, pH, Hco3, PCO2, TCO2, AG, BE
Reagent Pack : 700ml
1100ml
300 test with each pack*

Technical Specifications

Principle : Direct measurement with in selection electrode (ISE).
Parameter Conversion : This functionality allows quick change of analyze.
Sample : Whole blood, serum, plasma, CSF and diluted urine (dilution ratio 1:5).
Measuring time : 65 sec.
Data Storage : 600 serum/plasma, 100 urine, 100 QC.
Ambient conditions : Temperature 5oC - 40oC, < 85% non – condensing humidity.
Output : 128x64 graphics display with Y/N numeric keypad.
Printer : 24 column thermal printer, USB port.
Input Voltage : 100/115 VAC, 50-60 HZ or 220-VAC, 50-60Hz, 0.75amp.
Size & Weight : 30.1 cm W x, 35.cmH x 30.6cm D, 8.260kg.

Calculated Parameters TCO2, PCO2, BE, AG

Measuring Range CV %
8-12 YEARS 12-16 YEARS ABOVE 16
Na + 50.0-250.0 mmol/L <1.0%
K+ 0.50-20.00 mmol/L <2.0%
Cl- 45.0-200.0 mmol/L <2.0%
iCa++ 1.0-20.0 mmol/L <2.0%
Li+ 0.2-5 mmol/L <2.0%
pH 6.00-8.00 <2.0%
HCO3 22-28 mmol/L <2.0%

Inbuilt Parameter Selection

Mode A Na/K/Cl
Mode B Na/K/iCa
Mode C Na/K/iCa/pH
Mode D Na/K/iCa/Cl
Mode E Na/K/iCa/Li
Mode F Na/K/iCa/pH/Cl
Mode G /K/iCa/pH/Cl/HCO3